TLS-ZK Self-Expanding Bottom Mechanical Anchor
+
  • TLS-ZK Self-Expanding Bottom Mechanical Anchor

TLS-ZK Self-Expanding Bottom Mechanical Anchor

Fixing of various curtain wall mullion corner brackets, steel‑bonding or steel‑cladding anchorage, tension‑strengthening of bridge and road concrete structures, rail transit applications, anchorage for steel structures and heavy loads, fixation of high-speed railway catenary supports, installation and securing of tunnel escape and evacuation platforms, and post‑installed channel‑track fastening within tunnels.

Product Details



Grade And Material

5.8 Level / 8.8 Level 
Stainless steel  (5 0 / 70 / 80 )

Surface Anti-Corrosion

Electroplated galvanizing: average thickness ≥ 5μm
Hot dip galvanizing: average thickness ≥ 45μm

Anchor Composition

Screw, mechanical lock key, sleeve, nut, flat washer, spring washer

Various types of curtain wall keel bracket fixation, steel or steel clad fixation, road and bridge concrete tensioning reinforcement, rail transit, steel structure and heavy load anchoring, high-speed rail contact network support fixation, tunnel escape and evacuation platform installation fixation, and tunnel rear channel fixation.

Product Features

▲ Equipped with a built-in circular cutting edge, it can be installed with torque control for cutting into concrete or displacement control for cutting into concrete. The clever design minimizes expansion stress, has good durability, does not require enlarging the bottom of the hole, reduces construction technology, and accelerates construction speed.

Table of Drilling Depth and Diameter for Self Expanding Bottom Mechanical Anchors

Model

M10 M12 M16

Drilling Diameter  /  mm

16 18 22

Effective Burial Depth  /  mm

70 60 80 100 100 130

Anchor Plate Thickness  /  mm

20 20 20 25 30 30

Drilling Depth  /  mm

75 75 95 115 115 145

Screw Total Length  /  mm

130 100 140 160 160 190

Concrete Substrate Thickness  /  mm

150 120 160 200 200 240

Installation Pre Tightening Torque  /   N·m

60 80 120

Minimum Spacing  /  mm

85 110 135

Minimum Margin /  mm

85 110 220

Installation Process Diagram of Self Expanding Bottom Mechanical Anchor

 

Self Expanding Bottom Mechanical Anchor lnstallation Force Data

Prefabricated installation

Model

Effective Burial
Depth(mm)

Grade

Tensile Standard Value(kN)

Shear Standard Value(kN)

concrete strength ≥ C25

concrete strength ≥ C25

Crack

Non Cracking

Crack

Non Cracking

 

 

M10

40 5.8 9.7 13.6 11.6 11.6
70 5.8 17.8 23.2 11.6 11.6
40 8.8 9.7 13.6 18.6 18.6
70 8.8 17.8 24.9 18.6 18.6
40 304 9.7 13.6 13.0 13.0
70 304 17.8 24.9 13.0 13.0
40 316 9.7 13.6 17.4 17.4
70 316 17.8 24.9 17.4 17.4

 

 

 

M12

60 5.8 17.8 24.9 16.9 16.9
80 5.8 27.4 33.7 16.9 16.9
100 5.8 33.7 33.7 16.9 16.9
60 8.8 17.8 24.9 27.0 27.0
80 8.8 27.4 38.4 27.0 27.0
100 8.8 38.3 53.7 27.0 27.0
60 304 17.8 24.9 19.0 19.0
80 304 27.4 37.9 19.0 19.0
100 304 37.9 37.9 19.0 19.0
60 316 17.8 24.9 25.3 25.3
80 316 27.4 38.4 25.3 25.3
100 316 38.3 50.6 25.3 25.3

 

 

M16

100 5.8 38.3 53.7 31.3 31.3
130 5.8 50.4 62.7 31.3 31.3
100 8.8 38.3 53.7 50.1 50.1
130 8.8 50.4 70.6 50.1 50.1
100 304 38.3 53.7 35.3 35.3
130 304 50.4 70.5 35.3 35.3
100 316 38.3 53.7 47.0 47.0
130 316 50.4 70.6 47.0 47.0

 

 

M20

160 5.8 77.6 97.9 49.0 49.0
200 5.8 97.9 97.9 49.0 49.0
160 8.8 77.6 108.6 78.3 78.3
200 8.8 108.4 151.8 78.3 78.3
160 304 77.6 108.6 55.1 55.1
200 304 108.4 110.2 55.1 55.1
160 316 77.6 108.6 73.4 73.4
200 316 108.4 146.9 73.4 73.4

 

▲ The table data is applicable for: correct installation, no margin or distance influence, minimum substrate thickness. The table data is based on C25 substrate concrete, and if the substrate grade changes, the concrete strength influence coefficient should be added according to the specifications.

▲ The above table does not include any products. Please refer to the bearing capacity calculation methods in the "Technical Specification for Rear Anchoring of Concrete Structures" JGJ145-2013 and "Mechanical Anchors for Concrete" JG/T-2017 to verify and obtain the corresponding data. For specific details, please consult the Technical Department of Nanjing Telesun S&T Industry Co., Ltd

Installation Process Diagram of Self Expanding Bottom Mechanical Anchor

Self Expanding Bottom Mechanical Anchor lnstallation Force Data

Penetrating Installation

Model

Effective Burial
Depth(mm)

Grade

Tensile Standard Value(kN)

Shear Standard Value(kN)

concrete strength ≥ C25

concrete strength ≥ C25

Crack

Non Cracking

Crack

Non Cracking

 

 

M10

40 5.8 9.7 13.6 13.7 13.7
70 5.8 17.8 23.2 13.7 13.7
40 8.8 9.7 13.6 20.6 20.6
70 8.8 17.8 24.9 20.6 20.6
40 304 9.7 13.6 16.9 16.9
70 304 17.8 24.9 16.9 16.9
40 316 9.7 13.6 22.5 22.5
70 316 17.8 24.9 22.5 22.5

 

 

 

M12

60 5.8 17.8 24.9 22.2 22.2
80 5.8 27.4 33.7 22.2 22.2
100 5.8 33.7 33.7 22.2 22.2
60 8.8 17.8 24.9 32.4 32.4
80 8.8 27.4 38.4 32.4 32.4
100 8.8 38.3 53.7 32.4 32.4
60 304 17.8 24.9 28.9 28.9
80 304 27.4 37.9 28.9 28.9
100 304 37.9 37.9 28.9 28.9
60 316 17.8 24.9 38.5 38.5
80 316 27.4 38.4 38.5 38.5
100 316 38.3 50.6 38.5 38.5

 

 

M16

100 5.8 38.3 53.7 37.8 37.8
130 5.8 50.4 62.7 37.8 37.8
100 8.8 38.3 53.7 56.6 56.6
130 8.8 50.4 70.6 56.6 56.6
100 304 38.3 53.7 47.1 47.1
130 304 50.4 70.5 47.1 47.1
100 316 38.3 53.7 62.8 62.8
130 316 50.4 70.6 62.8 62.8

 

 

M20

160 5.8 77.6 97.9 59.2 59.2
200 5.8 97.9 97.9 59.2 59.2
160 8.8 77.6 108.6 88.6 88.6
200 8.8 108.4 151.8 88.6 88.6
160 304 77.6 108.6 73.9 73.9
200 304 108.4 110.2 73.9 73.9
160 316 77.6 108.6 98.5 98.5
200 316 108.4 146.9 98.5 98.5

 

▲ The table data is applicable for: correct installation, no margin or distance influence, minimum substrate thickness. The table data is based on C25 substrate concrete, and if the substrate grade changes, the concrete strength influence coefficient should be added according to the specifications.

▲ The above table does not include any products. Please refer to the bearing capacity calculation methods in the "Technical Specification for Rear Anchoring of Concrete Structures" JGJ145-2013 and "Mechanical Anchors for Concrete" JG/T-2017 to verify and obtain the corresponding data. For specific details, please consult the Technical Department of Nanjing Telesun S&T Industry Co., Ltd

Product Inquiry

*Note: Please ensure that all information is accurately provided and keep your contact details up to date. We will get in touch with you as soon as possible.

Submit