TLS-HM Chemical Anchor
Contact Us
Category
Product Details
|
Grade And Material |
5.8 Level / 8.8 Level Stainless steel (5 0 / 70 / 80 ) |
|
Surface Anti-Corrosion |
Electroplated galvanizing: average thickness ≥ 5μm |
|
Anchor Composition |
Screw, nut, flat washer |
▲ It is suitable for non cracking concrete and does not generate expansion or compression stress on concrete.
▲ It is suitable for fixed installation with small spacing and small margin, with wide anchorage depth range, fast curing speed, acid and alkali resistance, aging resistance and good heat resistance.
▲ It can adapt to high temperatures during welding and achieve pre-embedding effect after standardized planting.
▲ Various types of curtain wall bracket fixation, equipment installation fixation, bridge reinforcement, protective fence installation, highway sound barrier installation fixation, rail transit, advertising light box installation fixation, steel structure and concrete connection fixation.
Chemical Anchor Drilling Depth and Diameter Table
|
Model |
M8 | M10 | M12 | M16 | M20 | M24 | M30 |
|
Drilling Diameter / mm |
10 | 12 | 14 | 18 | 24 | 28 | 35 |
|
Effective Burial Depth / mm |
80 | 90 | 110 | 130 | 170 | 210 | 280 |
|
Anchor Plate Thickness / mm |
10 | 20 | 25 | 30 | 60 | 55 | 60 |
|
Drilling Depth / mm |
80 | 90 | 110 | 130 | 170 | 210 | 280 |
|
Screw Total Length / mm |
110 | 130 | 160 | 190 | 260 | 300 | 380 |
|
Concrete Substrate Thickness / mm |
104 | 115 | 140 | 170 | 220 | 270 | 350 |
|
Installation Pre Tightening Torque / N·m |
15 | 20 | 40 | 60 | 100 | 160 | 240 |
|
Minimum Spacing / mm |
50 | 60 | 72 | 96 | 120 | 144 | 180 |
|
Minimum Margin / mm |
50 | 60 | 72 | 96 | 120 | 144 | 180 |
|
360ml Injection Type Tendon Glue Planting quantity |
78 | 48 | 28 | 15 | 6 | 4 | 2 |
Schematic diagram of chemical anchor planting
L-Anchor Total Length / mm; L1 Effective Burial Depth / mm ;d Drilling Diameter / mm;t Anchor Thickness / mm
Wuhan Yangtze River Fourth Bridge

Related Technical Parameters
|
Model |
Effective Burial |
Grade |
Tensile Standard Value(kN) |
Shear Standard Value(kN) |
||
|
concrete strength ≥ C25 |
concrete strength ≥ C25 |
|||||
|
Crack |
Non Cracking |
Crack |
Non Cracking |
|||
| M8 | 80 | 5.8 | 3.8 | 6.3 | 3.6 | 3.6 |
| 8.8 | 3.8 | 6.3 | 3.6 | 3.6 | ||
| 304 | 3.8 | 6.3 | 3.6 | 3.6 | ||
| 316 | 3.8 | 6.3 | 3.6 | 3.6 | ||
| M10 | 90 | 5.8 | 5.7 | 17.0 | 11.6 | 11.6 |
| 8.8 | 5.7 | 17.0 | 18.6 | 18.6 | ||
| 304 | 5.7 | 17.0 | 13.0 | 13.0 | ||
| 316 | 5.7 | 17.0 | 17.4 | 17.4 | ||
| M12 | 110 | 5.8 | 8.3 | 24.9 | 16.9 | 16.9 |
| 8.8 | 8.3 | 24.9 | 27.0 | 27.0 | ||
| 304 | 8.3 | 24.9 | 19.0 | 19.0 | ||
| 316 | 8.3 | 24.9 | 25.3 | 25.3 | ||
| M16 | 130 | 5.8 | 13.1 | 39.2 | 31.3 | 31.3 |
| 8.8 | 13.1 | 39.2 | 50.1 | 50.1 | ||
| 304 | 13.1 | 39.2 | 35.3 | 35.3 | ||
| 316 | 13.1 | 39.2 | 47.0 | 47.0 | ||
| M20 | 170 | 5.8 | 21.4 | 64.1 | 49.0 | 49.0 |
| 8.8 | 21.4 | 64.1 | 78.3 | 78.3 | ||
| 304 | 21.4 | 64.1 | 55.1 | 55.1 | ||
| 316 | 21.4 | 64.1 | 73.4 | 73.4 | ||
| M24 | 210 | 5.8 | 31.7 | 95.0 | 70.5 | 70.5 |
| 8.8 | 31.7 | 95.0 | 112.8 | 112.8 | ||
| 304 | 31.7 | 95.0 | 79.3 | 79.3 | ||
| 316 | 31.7 | 95.0 | 105.8 | 105.8 | ||
| M30 | 280 | 5.8 | 52.8 | 158.3 | 112.1 | 112.1 |
| 8.8 | 52.8 | 158.3 | 179.4 | 179.4 | ||
| 304 | 52.8 | 158.3 | 126.1 | 126.1 | ||
| 316 | 52.8 | 158.3 | 168.2 | 168.2 | ||
Planting flowchart of chemical anchor with planting reinforcement glue